clack 3 button manualthe farm'' tennessee documentary

This manual is not intended to be used as a manual for a complete water softener or filter. Clack WS1.5_WS2_WS2QC Manual. arrow button. Easy do it yourself replacement - see video. The manual is designed to aid water treat ment equipment manufacturers in the selection of the various control valve options. Complete range of spares and parts for the Clack range of Valves. Step 3 - Current Time (minutes): Set the minutes of day using or buttons. (6) + button Select the number of copies, maintenance code, etc. Besides, it's possible to examine each page of the guide singly by using the scroll bar. View online or download 4 Manuals for Clack WS2 series. Open valve's inlet slowly 1/3 to fill mineral tank. Use the arrows at the Left or Right of the manual, or the arrows at the top Right of the screen, or the roller ball on your mouse to page forward or backward. EE Man u al Page 5 Range of times (min.) REGEN TODAY flashes in upper left corner of display between rotating display when RE-GEN button pushed once. Press and "hold" the PUSH button the LED indicator will blink: the unit will operate at maximum speed for 20 minutes. WS1.5CI & 2LCI Man u al Page 3 CI Front Cover and Drive Assembly Drawing No. USER DISPLAY 3 Displays present flow rate. *Used in WS1, WS1.25 and other valve models, also used in private lable valves for other companies. Replacement Circuit board for Clack TC Valve. Water Specialist 1" Control Valve Series Model: WS1TC 1.25. General instructions applicable to both softeners and filters. Press the button to turn on the radio and press the MODE button and select FM mode. 4. eh tsPser Set Up or Set Down buttons to set the amount of feed water hardness in grains/gallon (U.S.) or degrees (metric). Press the "REGEN" button once. The user cannot . When the WS1 control valve is manufactured as a softener, the control valve can be ordered . REGEN TODAY will ash on the display. S-2000_Clack_Timer_Valve. Durable 3 button metal chassis construction. To initiate a manual regeneration immediately, press and hold the "REGEN" button for three seconds. All plumbing should be done in accordance with local plumbing codes. Fleck 5600XST Downflow Manual. Step 1S - Press NEXT and simultaneously for 3 seconds and release. To see an online version of the software help file, please visit this page. We'll build to your specifications . 45,000 grain softener = 45.0. iv. Connector details: a. Terminate end with one Molex white housing, P/N 09-50-8043 and four Molex pins, P/N 08-50-0108. b. Pin 1 = 24.0 VAC White Pin 2 = Jumper to Pin 3 Pin 3 = Jumper to Pin 2 Pin 4 = 24.0 VAC Black Custom Meter Wiring: 1) Terminate end with a Molex series 2695 housing, part number 22-01-3037 and (3) Molex series 41572 (or It has a sturdy wooden construction, with smart turned wooden legs in a black finish, which adds to the elegant look of this sofa. IN STOCK. $25.00. The black center knob will make one revolution in the Gravel Media (qty as specified) 1.3 MISSING OR DAMAGED GOODS Immediately on receipt of the goods, it is advisable to check that all items ordered have been received. Make sure the water inlet and outlet are closed. VESSEL (c/w riser and distribution system) 5. Cycle 1 Backwash 5 5 5 5 5 5 5 5 5 5 5 5 Cycle 2 Brine dn 54 68 60 70 62 64 86 86 71 84 61 Cycle 3 Rinse 6 6 6 6 6 6 6 6 6 6 6 6 Cycle 4 Fill Kg 1.2 3 4.5 6 7.5 9 11.2 15 18.7 22.5 30 37.5 . Generation 5 Control Valve . 1. Press NEXT to exit Set Clock. * check your board or manual to see if this is . Fleck 2900S Manual. Press SET . Same day shipping on most orders made by 2 pm MST. The 1 distributor tube (1.050 O.D.) T-3 PUSH BUTTON TIMER (20/40/60 MINIUTES MAXIMUM VENTILATION SPEED) Press the PUSH button to activate or deactivate the T-3 Timer. Option 3 - Service Option 4 - Accounts Option 5 - Operator Option 6 - 24/7 Emergency Breakdown. clack control valve, clack valve, clack water softener parts, By Pass for Clack WS1 Valve, Fitting 1 Inch Brass Sweat for Clack,Spacer Stack Assy for Clack WS1, . Compact and portable its small foot-print takes very little space on stage or in your gig bag. CLACK WS1 PROGRAMMING SET TIME: Press SET CLOCK and adjust hour (check for am and pm). Clack Valve Reference Guide Web Link. the unit will operate at high speed for . Centronic VarioControl VC320 - Becker-Automatismos. Water Specialist AT Control Valve. Easy to install if you buy the tool. Replacement Circuit board for Clack TC Valve. With the valve's inlet and outlet closed, initiate a manual regeneration and follow these directions. Set the correct minutes by pressing either the or the arrow button. 5 control valve functions TECH-CS SERIES CONTROL VALVES. Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration. Click to Download User Manuals and Guides. Information in this manual is different than what is needed for installation and servicing of a particular water treatment system. Page 6 CI Man u al OEM Cycle Sequence OEM Cycle Sequence instructions allows the OEM to set the order of . POLARA iNX Push Button Station User Manual Operation & user's manual (26 pages) Bogen NYQUIST NQ-GA10P Installation And Use Manual Installation and use manual (12 pages) Top Brands All Brands . INSTRUCTIONS 4. Part Number V3818TC, 3M ID 70020286012, UPC 00016145268007, 3M Product Number V3818TC. 3. 2 . Clack WS1 3-Button Control Valve Manual. Refer to Control Valve Service Manual for other drawings and part numbers. Consumer's Manual Manufactured by: HELLENBRAND, INC. 1.25" Control Valve Series Model: WS1.25. Trouble Shooting Guide for WS1 and WS2. Then press the NEXT button. When theAlarm rings, if the alarm sound is BUZZ, press any button to stop or press button (4) to enter snooze mode. GPM Flashes when the turbine is rotating. Quantity 1 1 1 1 3 1 1. 4. 5 button metered clack valve 5 Button Straight Across. Clack No Hard Water Bypass Valves (1" or 1.25" V3070FF or V3070FM) are not designed to be used . clack spares. (9) Color button * Starts color copying. The Clack WS1 water softener 4 and 5 button valves can be locked, but just so you know not the 3 button time clock valves. To unlock press , NEXT, , and SET CLOCK in sequence, then press NEXT and simultaneously for 3 seconds and release. M2-Timer Manual titled Water Specialist EE Control Valve Programming Manual. Release the pressure inside the filter by pressing the REGEN button which will start a manual backwash, and instantly release the pressure. If you're looking for a quick and easy video on how to set time and program a Clack WS1 3 button valve you've found it here! How To Manually Regenerate Your Water Conditioner At . The pipe size for residential drain line should be a minimum of 1/2" (13 mm). Clack WS1CT and WS1.25CT Manual. . Page 4 EA Manual Drawing No. the unit will operate at high speed for 40 minutes. This manual is not intended to be used as a manual for a complete water softener or filter. Printed in U.S.A. Description Quantity 1 V3175EE-01 WS1EE FRONT COVER ASSEmBly 1 2 V3107-01 WS1 mOTOR 1 3 V3106-01 WS1 DRIVE BRACkET & SpRINg ClIp 1 4 V3408EA-03BOARD WS1THRU2l/2 EApCBRD mAV/AlT REpl 1 5 V3110 WS1 DRIVE gEAR 12x36 3 6 V3109 WS1 DRIVE gEAR COVER 1 Not Shown V3186 WS1 AC ADApTER 110V-12V 1 V3186-01 WS1 AC . Manuals for Charger Water Products. arrow button. Page 4 EA Manual Drawing No. However, running a manual regeneration during commissioning is the best way of removing air from the softener, bedding in the resin and flushing the softener through. Shipping & Returns. Control Board V3818TC, 3 Button Clack, For 3M Water Softener Systems, 1 Per Case. Clack WS1 Dot Matrix Manual. Feed water hardness (Display Code H). If these manuals are not helpful or right for your model then you can try calling the Clack water softener number on 608-846-3010. The manual is designed to aid water treat ment equipment manufacturers in the selection of the various control valve options. Reviewed in the United States on March 26, 2022. This manual is not intended to be used as a manual for a complete water softener or filter. Let the valve advance to A KWASH. FLECK 5600 CONTROL VALVE. All Clack valves incorporate patented* "stack technology" and feature state-of-the-art electronics and programming software. Product Code: CLK V3108CC ***VISIT TODAY*** Clack WS1 5 Button Valve Circuit Board Replacement Circuit board for Clack C1 and CC Valve - note 5 button configuration on front. Becker R40/17C Operating instructions. Report abuse. Clack WS1 Manual. System Setup, Press NEXT and DOWN simultaneously for 3 seconds and release. . Any Time 1. 30,000 grain softener = 30.0. iii. Press button (1) again when the volume indicator flashes on display, press button (3) or (5) to adjust volume to your ideal level. . You can press this button to cancel a print, copy, or scan job in progress. 1. ACTIVATED CARBON MEDIA (qty as specified) 7. LATEST NEWS; *this is the newer version of the board which has a battery back up and a slightly larger display. 3. A 10' stereo TRS cable is included with each unit. . Fleck Iron . 5.0 out of 5 stars Fixed draining problem. Water Softeners; Repair Parts & Components; Drinking Water; Home Filtration; . Order No. Clack WS1 Iron Breaker III Programming with Ozone Manual. Clack WS1 Manual. Fleck 5600 Manual. Step 1S - Press NEXT and simultaneously for 3 seconds and release. Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration. BUTTON SKIPPER WHEEL (SHOWS EVERY OTHER DAY REGENERATION) TIME OF DAY ARROW RED POINTER. Press the NEXT button. Clack Corporation ("Clack") warrants . Clack WS1 3 Button Valve Circuit Board. The display will no longer be flashing . INSTRUCTIONS 4. WS1 & 1.25 TC 3 button Service Manual WS1 & 1.25 Service Manual WS1CS & 1.25CS Service Manual WS1.5, WS2 & WS2QC Service Manual WS2H & WS3 Service Manual WS1 & WS1.25 Drawings and Service Manual Prices From 2222.03. Press the operating manual water conditioner . The back of the sofa splits in two, so each side . Page 6 WS1 & 1.25 Man u al Control Valve Function and Cycles of Operation This glass lled Noryl1 (or equivalent) fully automatic control valve is designed as the primary control center to direct and regulate all cycles of a water softener or lter. DIY Video Library. Instrucciones para el montaje y manual de instrucciones. If screen in Step 2S does not appear in 5 seconds the lock on the valve is activated. Refer to the Service Manual for drawings and part numbers. Contact: Cleaver Brooks Co., 221 Law St., Thomasville GA 31792 USA, Tel: 800-250-5883 Email: info@cleaver-brooks.com Website: cleaverbrooks.com 6 5. The user cannot . Step 2 After all wiring connections have been made and veri ed, plug the System Controller power cord into an approved electrical outlet with uninterrupted power. programming the valve section page 7). 4" - 2 1/2" REDUCER (if required) 6. For this step, you need to program the pounds of salt that are used per. the chart below: i. Review M1 Manual pages 25-28 to familiarize yourself with basic do's and don'ts of valve use and installation and pages 32 & 33 for full flow by-pass valve details. PLANTRONICS + POLYCOM. Clack WS2H Parts 7 Products; Clack WS3 Parts 16 Products; Free Shipping on Orders Over $50. info@industrialwaterequipment.co.uk. 4" - 2 1/2" REDUCER (if required) 6. C3190130 -- WS1 13.0 GPM DLFC BUTTON 1" $6.15. Helpful. $19.95. If you have a clack s1 this seal pack will stop the water from running 24/7 if indeed the seal pack was you problem. 60,000 grain softener = 60.0. 3. Home; Products. User 5 Shows current time. 3. Now install your water pipes to the Clack WS1 bypass end connectors. Make sure the water inlet and outlet are closed. Press the or button until the correct hour is displayed. Free Shipping Eligibility. shopping_cart Add to Cart; sort; New. 2. NOTE: The feed water hardness setting only displays when the system is set to operate as a Meter Immediate or Meter Delayed system type. "REGEN TODAY" will not activate if "REGEN" button is pressed. Clack MANUAL 3. PYROLOX MEDIA (qty as specified) 1.3 MISSING OR DAMAGED GOODS Immediately on receipt of the goods, it is advisable to check that all items ordered have been received. The pipe size for the drain should be a minimum of 1/2. Clack No Hard Water Bypass Valves (1" or 1.25" V3070FF or V3070FM) are not designed . visibility Quick View; C3190250 -- WS1 25.0 GPM DLFC 1" . Service Manual. However, running a manual regeneration during commissioning is the best way of removing air from the softener, bedding in the resin and flushing the softener through. Part # V3818TC, V3818-01. Set the dial on the front of the unit to any regeneration time between 15 minutes and 3 hours. Press REGEN button and hold button for 3-5 seconds for immediate regen. WS 1.5 EE Manual Drive Cap Assembly, Downow Piston, Regenerant Piston, Spacer Stack Assembly, Drive Back Plate, Main Body and Meter Drawing No . SET with SOFTENING flashing should appear on screen. Web: www.hellenbrand.com Email: info@hellenbrand.com 800540 Rev D 3/01/18-LBRY 2014-2018. If screen in Step 2S does not appear in 5 seconds the lock on the valve is activated. 3.5 gpm 4.0 gpm 14 . . Set the correct minutes by pressing either the or the arrow button. Manufactuered by Clack Corporation. For Professionals; For Homeowners; 855-848-7899 . SW VALVE/OPERATIONS. Clack WS1TC Manual. Refer to Control Valve Service Manual for other drawings and part numbers. If Alarm sound is Radio, the radio will keep playing . USING THE RADIO 1. 2. Product Code: CLK V3108TC. STEP 2S STEP 3S Step 2S - Choose SOFTENING using the or button. Page 4 1 20 16 15 19 22 Product Code: CLK V3108TC. 3. 3. 2010 300 415 0 MBA Modell C01 PROF+ en - Becker. For all Clack water softener manuals see this page: CLACK WATER SOFTENER MANUALS; Cleaver Brooks Water Conditioners . Easy do it yourself replacement - see video. 2 3. Three Buttons. This manual is for CLICK PLC hardware. In many ways, the Clack water softener valve has the best of all the others. Whether your valve is on a wate. Distributieweg 3 2645 EG Delfgauw The Netherlands Phone: +31 152 610 900 fax: +31 152 616 289 e-mail: info@lenntech.com. Here are links to the most requested Clack water softener manual. Wait for the regeneration cycle to finish and look at the display to check if there was a salt shortage or not. Reviews. m3017-w100sm 1.25/1.5 13 x 65 3 18 x 36 300 90k 60k 45 18 21 15 5.3 m3019-w100sm 1.25/1.5 16 x 65 4 18 x 36 300 120k 80k 60 24 22 15 7.5 m3021-w100sm 1.25/1.5 21 x 62 7 24 x 41 600 210k 140k 105 42 24 15 11.0. Add To Cart. Literature Spec Sheet Manual (Post-feb 2018) Manual (Pre-feb 2018) Impression Plus AirCat: Impression Plus Air Iron & Air Sulfur: Impression Plus Tannin All plumbing must be done in accordance with local plumbing codes. Down Load WS1, WS1.25 Manual NOTE: Several other "Brands" now use the Clack type of valve under their private label. Don't see what you need? regeneration cycle for your softener. Press REGEN to return to previous step. System Setup, Press NEXT and DOWN simultaneously for 3 seconds and release. programming the valve section page 7). Order No. clack 3 valves. User screens will continuously scroll, switching views every 3 seconds. Clack MANUAL 3. Manuals and Technical Information; Blog; About; Contact; Account $ 0.00 Cart. Return the switch to the ON position (this enables your water softener). Backwash flow rates in excess of 7 gpm or length in excess of 20 require 3/4 drain line. Clack WS1CS-1.25 Manual - Vibrant Water Purification Systems. P5/16PR+ - P9/16PR+ - Becker. IN STOCK. The following general warnings and the specifications in Table 1 must appear in the OEM's System Manual. The highly-rated SpringWell FutureSoft Salt-Free Water Softener provides 99.6% scale prevention without the use of chemicals or salt and ensures you have a zero drop in water pressure throughout your home. Lenntech USA LLC (Americas) 5975 Sunset Drive wiring, reference the V3115-46 or V3115-48 System Controller Manual. The FS3X provides increased functionality and convenient Hands-free control over UP/DOWN selection of Models, Mode changes, Loop selection, auto START/STOPS and arms auto record where applicable. 3. Clack WS1TC Manual. view range. Setting Time of Day Push NEXT button until time of day screen is displayed. Step 5: The minute display will now be flashing. . Clack Corporation Water Softeners & Control Valves & Manuals. Secure Online . This slight movement of the manual regeneration knob engages the program wheel and starts the regeneration program. Clack Water Softener Manual. Page 35 addresses inlet and outlet . You can also press this button to finalize your selection for the setting item. Set 3 Set 4 Set 5 Step 2. The Clack WS1 is the most common Clack valve on the market and is used and sold under many different "brand" names. 5. Release the button when the unit is receiving a station you would like to listen to. cfm. Clack No Hard Water Bypass Valves (1" or 1.25" V3070FF or V3070FM) are not 5. The valve acts as a primary center that directs and regulates all cycles of water softening or filtration. 1" Control Valve Series Model: WS1. 3 V3106-01 WS1 DRIVE BRACKET & SPRING CLIP 1 4 V3408EA-03BOARD WS1THRU2L/2 EAPCBRD MAV/ALT REPL 1 5 V3110 WS1 DRIVE GEAR 12X36 3 6 V3109 WS1 DRIVE GEAR COVER 1 Not Shown V3186 WS1 AC ADAPTER 120V-12V 1 V3186-01 WS1 AC ADAPTER CORD ONLY Not Shown V3178 WS1 Drive Back Plate 1 EA Front Cover and Drive Assembly 1 4 6 5 3 2 AC Adapter U.S. International WS1 & WS1.25 Drawings & Service Manual Page 11 6 2 4b 4a 5 1 3 7 8 WS1 Drive Cap Assembly, Downfl ow Piston, Upfl ow Piston, Regenerant Piston and Spacer Stack Assembly Drawing No. Fleck 2850S Manual. Sulfur Filter/Chem Free Iron Valve 3 over 2 button clack. Turn the manual regeneration knob clockwise. FOR 3 SECONDS TO RESET TO 0. Order No. Press and hold one of the buttons to start automatic tuning up/down. For manual fine-tuning, you can press it briefly to adjust the frequency step by step. Clack WS1CT and WS1.25CT Manual. Order No. Clack WS3 Water Filter Valves. Backwash flow rates in excess of 7 gpm or length in excess of 20' require 3/4" drain line. Model 7000 9 Programming a Meter Delayed Regenerated System 1. The FutureSoft from SpringWell is a whole house salt-free water softener that is made by one of the best companies in the water filtration and softening business.. FREE Shipping You can get the BEST Clack WS1 5 Button Valve Circuit Board - Replacement Circuit board. view range. Clack WS1 Dot Matrix Manual. To maintain your 3M product, use only the spare parts listed in your instruction manual; This beautiful deep blue velvet click clack sofa features a diamond tufted backrest and low arms which gives it a traditional look. d. When display shows SET / CAPACITY, use the up or down button to change value to the correct size softener you have. The AM/PM indicator will toggle after the hour reaches 12. We don't lock them but some water softener assemblers like Viqua do and if you want to get you in to change the programming you'll need to unlock the valve first. (7) Stop button Cancels operations. 20,0000 grain softener = 20.0. ii. Generation 7 Control Valve. Clack WS1 3 Button Valve Circuit Board. It has few moving parts, is cheap to repair, and is extremely reliable. Clack's WS1 Automatic valve is a state-of-the-art control head designed for residential and commercial applications requiring flow rates up to 27 GPM (6.1 m/hr). Press and hold the regeneration button for 3 seconds. Control Valve Function and Cycles of Operation Page 1 WS1TC & WS1.25 TC Manual Control Valve Function and Cycles of Operation This glass lled Noryl1 (or equivalent) fully automatic control valve is designed as the primary control center to direct and regulate all cycles of a down ow regeneration water softener or lter. Once the correct value is displayed press NEXT. Water Specialist Control Valves. 2. View / Download the Complete Manual. Clack is the new kid on the block; but there are some good reasons to prefer it. VESSEL (c/w riser and distribution system) 5. Click the link above to view the complete manual. After the pressure is released you can remove the filter from the pipes by unscrewing . SET with SOFTENING flashing should appear on screen. 4. For example, if you have a 1 cubic foot unit, set the number to 27.0x1000, if you have a 1.5 Description Quantity 1 V3175CC-01 WS1CC FRONT COVER ASSEMBLY 1 2 V3107-01 WS1 MOTOR 1 3 V3106-01 WS1 DRIVE BRACKET & SPRING CLIP 1 4 V3108CI-02BOARD WS1 THRU2L CI PCBRD ALT REPLACE 1 5 V3110 WS1 DRIVE REDUCING GEAR 12X36 3 6 V3109 WS1 DRIVE GEAR COVER 1 Not Shown In comparison with all the other valves on our list, we give the Clack 4.5 out of 5 stars. During cold weather, the installer should warm the valve to room temperature before operating. Information in this manual is different than what is needed for installation and servicing of a particular water treatment system. 3. Operating Instructions. A. Clack WS2H and WS3 Manual. . Note: Only use silicone lubricant. Overview. Certain parts of the manual will serve as aids to manufacturers in the writing and layout of the manuals for installers and service personnel. Description Quantity 1 V3175EE-01 WS1EE FRONT COVER ASSEmBly 1 2 V3107-01 WS1 mOTOR 1 3 V3106-01 WS1 DRIVE BRACkET & SpRINg ClIp 1 4 V3408EA-03BOARD WS1THRU2l/2 EApCBRD mAV/AlT REpl 1 5 V3110 WS1 DRIVE gEAR 12x36 3 6 V3109 WS1 DRIVE gEAR COVER 1 Not Shown V3186 WS1 AC ADApTER 110V-12V 1 V3186-01 WS1 AC . Clack Circuit Board for the 5 button Clack WS1 and the WS1.25 - Clack Part #V3108 - This latest version of the Clack circuit board for the WS1 and WS1.25 control valves replaces older versions of the board. 4. 3. Step 5: The minute display will now be flashing. Cycle 1 Backwash 5 5 5 5 5 5 5 5 5 5 5 5 Cycle 2 Brine dn 54 68 60 70 62 64 86 86 71 84 61 Cycle 3 Rinse 6 6 6 6 6 6 6 6 6 6 6 6 Cycle 4 Fill Kg 1.2 3 4.5 6 7.5 9 11.2 15 18.7 22.5 30 37.5 . should be cut flush with top of each tank. Release the red button to again engage the drive gear. Step 3 Program all control valves to the OEM's speci cations for the application and size of the units. Cover of Valve for 4 button WS1EE Clack Valve PN V3175EE-01. Search. Filtration Perfecteau inc. - tte de contrle CLACK WS1CS WS1 25CS. are in the correct location. Allow air to escape (listen until spurting stops). Download Clack Valve Service Manuals from Clack Corporation's website. Page 10. (8) Black button * Starts black & white copying. Clack WS1CH Quick Start Manual. Press and hold the regeneration button for 3 seconds. NOW TOGETHER ASBlackwire 3300 SeriesUser Guide Contents hide 1 Overview 2 Setup and software 2.1 Power and setup 2.2 Load software 3 Fit 3.1 Adjust the headband 3.2 Position the boom 3.3 Adjust the boom 4 Basics 4.1 Make/take/end calls 4.2 Volume 4.3 Mute 5 Troubleshooting 5.1 Headset 6 Support 7 Documents Continue reading "poly Blackwire 3300 Series User Guide" Press and hold the or arrow until the SET indicator is displayed, and the hour ashes. STEP 2S STEP 3S Step 2S - Choose SOFTENING using the or button. Battery replacement is 3 volt lithium coin cell type 2032. . 4. . Set 3 Set 4 Set 5 Step 2. The AM/PM indicator will toggle after the hour reaches 12. REGEN TODAY will ash on the display. If you have any doubt that goods have been Description Quantity 1 V3005 WS1 Spacer Stack Assembly 1 2 V3004 Drive Cap ASY 1 3 Back Plate Refer to Programming and Cover Drawing Manual 1 . Installation Manual PS(+) If the screens are manu-ally scrolled, this screen will remain constant for Press the NEXT button to exit the programming. Clack WS1TC Filter Valves User Manual. 3 Button Timer Clock Control Valve. Press the NEXT button. Press button (1) to confirm and exit setting. . Press the REGEN button once. Press NEXT . With Battery Back Up. Press NEXT . To unlock press , NEXT, , and SET CLOCK in sequence, then press NEXT and simultaneously for 3 seconds and release. The minutes will ash. Cover of Valve for 3 button WS1 Clack Valve V3175TC-01. Clack 3/4" Male Drain Elbow Assembly for the WS1 and WS1.25 Valves, 3/4" MNPT Connection Part # V315801 or V3158-01 this is the new improved update version! Read More $15.95 Manual. Clack WS1 3-Button Control Valve Manual. Manual Backwashing System MBW . 3 Double click on a page to quickly enlarge it and the same to return to normal size. It has a backwash abilitiy capable of servicing up to 22" diameter tanks. MODEL 5600 & 5600 ECONOMINDER . Problems viewing our PDF files? The default setting for this option is 2:00 AM. Individual chapters and appendicies may be downloaded below. The default setting for this option is 2:00 AM. Make sure inlet is installed to the 'In" . Fleck Metering . The display will no longer be flashing . Press the NEXT button to exit the programming. 2. 2. Deep Blue Velvet Tufted Sofa Bed. WS1 and WS1.25 Drawings & Service Manual. Clack WS2H and WS3 Manual. Read more.